| Intended use |
Single-family homes |
Single-family homes |
Single-family homes |
Single-family homes |
| Hydraulic drive |
Indirect 2:1 |
Indirect 2:1 |
Indirect 2:1 |
Indirect 2:1 |
| Speed |
0,15 m/s | 0,3 m/s1 |
0,15 m/s | 0,3 m/s1 |
0,15 m/s | 0,3 m/s1 |
0,15 m/s | 0,3 m/s1 |
| Nominal load |
180 kg ÷ 500 kg |
180 kg ÷ 500 kg |
180 kg ÷ 320 kg |
180 kg ÷ 320 kg |
| Maximum travel |
14 m |
14 m |
14 m |
12.5 m |
| Maximum number of passengers |
6 |
6 |
6 |
4 |
| Maximum number of stops |
8 |
8 |
8 |
5 |
| Number of trips with battery |
- |
- |
- |
10 a 16 |
| Minimum ditch |
120mm |
120mm |
120mm |
120mm |
| Flight |
2500mm | 2700mm (puerta 3AT) |
2500mm | 2700mm (puerta 3AT) |
2500mm | 2700mm (puerta 3AT) |
2500mm | 2700mm (puerta 3AT) |
| Engine power |
Single phase from 1.5kW to 3.4 KW at 50 and 60HZ |
Single phase from 1.5kW to 3.4kW at 50 and 60HZ |
Single phase from 1.5kW to 3.4kW at 50 and 60HZ |
Single phase at 2.2kW at 50Hz or battery powered |
| Mechanics |
Backpack chassis for single access and double access opposite/adjacent |
Backpack chassis for single access and double access opposite/adjacent |
Backpack chassis for single access and double access opposite/adjacent |
Backpack chassis for single access and double access opposite/adjacent |
| Cabin |
500 ÷ 1400 mm (width) 600 ÷ 1400 mm (deep) |
500 ÷ 1400 mm (width) 600 ÷ 1400 mm (deep) |
500 ÷ 1400 mm (width) 600 ÷ 1400 mm (deep) |
500 ÷ 1400 mm (width) 600 ÷ 1400 mm (deep) |
| Compliance with directives and standards |
Machinery Directive 2006/42/EC, EN 81-41 (safety) EN 81-70 (accessibility)2 |
Machinery Directive 2006/42/EC, EN 81-41 (safety) EN 81-70 (accessibility)2 |
Machinery Directive 2006/42/EC, EN 81-41 (safety) EN 81-70 (accessibility)2 |
Machinery Directive 2006/42/EC, EN 81-41 (safety) EN 81-70 (accessibility)2 |
| Hydraulic components |
Central HL DRY con armario Compact
(350mmx260mmx2000mm) (anchoxprofundoxalto) |
Central HL DRY con armario E400
(700mmx420mmx1500mm) (anchoxprofundoxalto) |
Central HL DRY con armario E400
(700mmx420mmx1500mm) (anchoxprofundoxalto) |
Central HL DRY con armario ZW
(655mmx385mmx1800mm) (anchoxprofundoxalto) |
| Safety components |
• Instant parachute device. • CE certified parachute valve. • Reduced pit device for maintenance. • Acoustic and luminous overload indicator. • Photoelectric barrier at each entrance. |
• Instant parachute device. • CE certified parachute valve. • Reduced pit device for maintenance. • Acoustic and luminous overload indicator. • Photoelectric barrier at each entrance. |
• Instant parachute device. • CE certified parachute valve. • Reduced pit device for maintenance. • Acoustic and luminous overload indicator. • Photoelectric barrier at each entrance. |
• Instant parachute device. • CE certified parachute valve. • Reduced pit device for maintenance. • Acoustic and luminous overload indicator. • Photoelectric barrier at each entrance. |
| Mechanical part |
• 2:1 chassis. • Instant parachute safety device. • Mechanical system to perform the chassis parachute test. • T82 guides in 5m sections. |
• 2:1 chassis. • Instant parachute safety device. • Mechanical system to perform the chassis parachute test. • T82 guides in 5m sections. |
• 2:1 chassis. • Instant parachute safety device. • Mechanical system to perform the chassis parachute test. • T82 guides in 5m sections. |
• 2:1 chassis. • Instant parachute safety device. • Mechanical system to perform the chassis parachute test. • T82 guides in 5m sections. |
| Electrical part |
• Electrical panel with universal or constant pulsation operation. • Button panel on each landing. • Stop button for emergencies in the cabin. • Alarm button. • Emergency light. |
• Electrical panel with universal or constant pulsation operation. • Button panel on each landing. • Stop button for emergencies in the cabin. • Alarm button. • Emergency light. |
• Electrical panel with universal or constant pulsation operation. • Button panel on each landing. • Stop button for emergencies in the cabin. • Alarm button. • Emergency light. |
• Electrical panel with universal or constant pulsation operation. • Button panel on each landing. • Stop button for emergencies in the cabin. • Alarm button. • Emergency light. |
| Certificates |
• EMC certificate for the control panel and the NGV electronic valve. • Certificate for fire-rated landing door. • CE certificate for parachute valve, door locks and chassis parachute devices. |
• EMC certificate for the control panel and the NGV electronic valve. • Certificate for fire-rated landing door. • CE certificate for parachute valve, door locks and chassis parachute devices. |
• EMC certificate for the control panel and the NGV electronic valve. • Certificate for fire-rated landing door. • CE certificate for parachute valve, door locks and chassis parachute devices. |
• EMC certificate for the control panel and the NGV electronic valve. • Certificate for fire-rated landing door. • CE certificate for parachute valve, door locks and chassis parachute devices. |