Improve your productivity. 4 keys to connecting the motor of a GMV hydraulic elevator

The correct connection of the motors used to operate elevators, hoists, lifts, etc. is as important as choosing the right motor for each installation.

Before connecting it, we must check:

  1. The characteristics of the motor we are going to use (in all GMV central units this information is identified above the terminal box).

engine tag

2. The online voltage at the installation.

Depending on what we have, we must make the appropriate connection.

Below we show the wiring diagram of the motors used in GMV power plants:

 

engine table

Example: If the line voltage in the installation is 400 three-phase. In case of having a direct start in a 230/400 motor, it will have to be connected in star, but if we have 400/690 it will be connected in delta.

U1, U2, V1, V2, W1, W2 = Central terminals

changeover time
START

ESTRELLA 1.2 SEG

 

IN OPERATION

(TRIANGLE)

Possible situations that arise from incorrect connections:

Frequently Asked Questions

If a correct connection is not made, the following may occur:

faqs motor

For more information, contact GMV's technical or commercial department:

Related link: Starting modes of an electric motor (I)